Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 174(1): 94-101, 2017 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-27009246

RESUMO

Under International Atomic Energy Agency regional programme TSA3 Radiological Protection of Patients in Medical Exposures, Latin American countries evaluated the image quality and glandular doses for digital mammography equipment with the purpose of seeing the performance and compliance with international recommendations. Totally, 24 institutions participated from Brazil, Chile, Costa Rica, El Salvador, Mexico, Paraguay and Venezuela. Signal difference noise ratio results showed for CR poor compliance with tolerances; better results were obtained for full-field digital mammography equipment. Mean glandular dose results showed that the majority of units have values below the acceptable dose levels. This joint Latin American project identified common problems: difficulty in working with digital images and lack of specific training by medical physicists from the region. Image quality is a main issue not being satisfied in accordance with international recommendations; optimisation processes in which the doses are increased should be very carefully done in order to improve early detection of any cancer signs.


Assuntos
Mamografia , Exposição à Radiação , Intensificação de Imagem Radiográfica , Brasil , Chile , Costa Rica , Humanos , México , Inquéritos e Questionários
2.
Radiat Prot Dosimetry ; 163(4): 473-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24993012

RESUMO

Latin American countries (Argentina, Brazil, Chile, Costa Rica, Cuba, Ecuador, El Salvador, Guatemala, Mexico, Nicaragua, Paraguay, Uruguay and Venezuela) working under the International Atomic Energy Agency (IAEA) Technical Cooperation Programme: TSA3 Radiological Protection of Patients in Medical Exposures have joined efforts in the optimisation of radiation protection in mammography practice. Through surveys of patient doses, the region has a unique database of diagnostic reference levels for analogue and digital equipment that will direct future optimisation activities towards the early detection of breast cancer among asymptomatic women. During RLA9/057 (2007-09) 24 institutions participated with analogue equipment in a dose survey. Regional training on methodology and measurement equipment was addressed in May 2007. The mean glandular dose (DG) was estimated using the incident kerma in air and relevant conversion coefficients for both projections craneo caudal and mediolateral oblique (CC and MLO). For Phase 2, RLA9/067 (2010-11), it was decided to include also digital systems in order to see their impact in future dose optimisation activities. Any new country that joined the project received training in the activities through IAEA expert missions. Twenty-nine new institutions participated (9 analogue and 20 digital equipment). A total of 2262 patient doses were collected during this study and from them D(G) (mGy) for both projections were estimated for each institution and country. Regional results (75 percentile in mGy) show for CC and MLO views, respectively: RLA9/057 (analogue) 2.63 and 3.17; RLA/067: 2.57 and 3.15 (analogue) and 2.69 and 2.90 (digital). Regarding only digital equipment for CC and MLO, respectively, computed radiography systems showed 2.59 and 2.78 and direct digital radiography (DDR) systems 2.78 and 3.04. Based on the IAEA Basic Safety Standard (BSS) reference dose (3 mGy), it can be observed that there is enough room to start optimisation processes in Latin America (LA); several countries or even particular institutions have values much higher than the 3 mGy. The main issues to address are lack of well-established quality assurance programmes for mammography, not enough medical physicists with training in mammography, an increase in patient doses with the introduction of digital equipment and to create awareness on radiation risk and optimisation strategies.


Assuntos
Mamografia/métodos , Energia Nuclear , Proteção Radiológica/normas , Neoplasias da Mama , Feminino , Inquéritos Epidemiológicos , Humanos , Agências Internacionais , América Latina , Doses de Radiação
3.
Eur Radiol ; 23(3): 623-31, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22940731

RESUMO

OBJECTIVE: To survey procedures and protocols in paediatric computed tomography (CT) in 40 less resourced countries. METHODS: Under a project of the International Atomic Energy Agency, 146 CT facilities in 40 countries of Africa, Asia, Europe and Latin America responded to an electronic survey of CT technology, exposure parameters, CT protocols and doses. RESULTS: Modern MDCT systems are available in 77 % of the facilities surveyed with dedicated paediatric CT protocols available in 94 %. However, protocols for some age groups were unavailable in around 50 % of the facilities surveyed. Indication-based protocols were used in 57 % of facilities. Estimates of radiation dose using CTDI or DLP from standard CT protocols demonstrated wide variation up to a factor of 100. CTDI(vol) values for the head and chest were between two and five times those for an adult at some sites. Sedation and use of shielding were frequently reported; immobilisation was not. Records of exposure factors were kept at 49 % of sites. CONCLUSION: There is significant potential for improvement in CT practice and protocol use for children in less resourced countries. Dose estimates for young children varied widely. This survey provides critical baseline data for ongoing quality improvement efforts by the IAEA.


Assuntos
Acessibilidade aos Serviços de Saúde/estatística & dados numéricos , Pediatria/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Proteção Radiológica/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , África/epidemiologia , Ásia/epidemiologia , Europa (Continente)/epidemiologia , Pesquisas sobre Atenção à Saúde , Humanos , América Latina/epidemiologia , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...